Screening platform

Test fast in complex media. Then automate the screen.

P4SPR 2.0, P4PRO with AffiPump and the AffiSampler on one bench, run from Affilabs.core. Try conditions in minutes on the P4SPR 2.0, then let the AffiSampler run your concentration series and plates on its own.

Screening platform: P4PRO on the AffiSampler, with the AffiPump and P4SPR 2.0
96 · 384well plates, or 2 mL vials
4 channelson each instrument
5–100 µLper flow injection
1 queuefor the whole platform
P4SPR 2.0

01 · Find the conditions

Work fast in complex media

On the P4SPR 2.0

Run static tests straight in serum, plasma or cell lysate. Change the surface, the buffer or the regeneration and see the answer in minutes, before you commit a single plate.

  • Static SPR: no pump, no tubing to prime
  • Four channels read in turn, with a reference channel on the same chip
  • The same sensors and surface chemistry as the flow line
Explore P4SPR 2.0 →
P4PRO with AffiPump on the AffiSampler

02 · Run it at scale

Automate concentration analysis and screening

On the P4PRO with AffiPump and the AffiSampler

Once the conditions work, queue the run. The AffiSampler takes each sample from a plate or vial and injects it into the P4PRO with AffiPump, cycle after cycle. Affilabs.core then overlays the cycles and fits concentrations and kinetics: kon, koff and KD.

  • 96- and 384-well plates (flat or deep) or 2 mL vials, in a cooled sample compartment
  • Needle washed automatically after every injection
  • Pump-controlled flow from 0.3 to 10,000 µL/min
  • Concentrations, contact times and regeneration set per cycle in one method
Explore P4PRO with AffiPump →

How one cycle runs

The AffiSampler fills the same sample loop you would fill by hand, so a method developed manually runs unchanged.

  1. Pick the wellAffilabs.core tells the AffiSampler which vial or well to sample.
  2. Draw the sampleThe autosampler draws it into its needle.
  3. Load the loopIt pushes the sample into the P4PRO sample loop.
  4. InjectThe P4PRO switches its valve and the AffiPump carries the sample over the sensor.
  5. WashThe needle is washed and the next cycle starts.
Screening platform installed on a lab bench: AffiSampler with P4PRO on top, AffiPump and Affilabs.core showing a live binding curve

In the field

Installed and running in a university lab

The full platform is installed in a university research lab, from static tests in complex media to automated screening, all run from one software. We qualified it on site and trained the team.

Specifications

InstrumentsP4SPR 2.0 (static) · P4PRO with AffiPump (static and flow) · AffiSampler autosampler
TechnologyLensless SPR (patented)
Channels4 per instrument; on the P4PRO, flow in channel pairs A/C and B/D
Sample carriers96-well plates (flat or deep well) · 384-well plates (flat or deep well) · 2 mL screw vials (12 or 54 positions) · 0.4 mL micro-vials
Sample compartmentCooled
InjectionAffiSampler fills the P4PRO sample loop; the AffiPump delivers 5–100 µL over the sensor
Flow rate0.3–10,000 µL/min
Kinetics rangekon 10³–10⁷ M⁻¹s⁻¹ · koff 10⁻⁵–10⁻¹ s⁻¹
SoftwareAffilabs.core: one method and one queue for the autosampler, the pump and both instruments
AffiSampler size330 × 540 × 300 mm, 16–19 kg
Power and connection100–240 VAC, 50/60 Hz · network cable to the control PC
Detection limits and volumes for each instrument are on the P4SPR 2.0 and P4PRO with AffiPump pages.

We install it, and we stay with you

InstallationWe set up the platform in your lab and configure the AffiSampler for your plates and vials.
QualificationThe complete system is qualified on site before your first run.
TrainingHands-on training for your team, with a live binding run.
SupportOnline manuals for your setup, yearly preventive maintenance, and a scientist to answer your questions.