Lensless SPR

SPR precision, moved from the optics to the signal.

Inside every P4SPR 2.0 and P4PRO is a Kretschmann SPR instrument with the complex optics taken out.

Patented · Kretschmann · wavelength interrogation

Lensless optical block
Illustration: the lensless optical block inside the outline of a conventional SPR bench (dashed): source, lenses, prism, detector. Same light path, without the parts.

HOW IT WORKS

How SPR measures binding

Binding on the gold moves a dip in the light. Following that dip over time gives the sensorgram.

THE DESIGN

Three design decisions

01

Keep the Kretschmann configuration

The same physics as conventional SPR, on purpose. Sensor surfaces, chemistries and published methods all carry over.

02

Streamline the optics

Every component the measurement didn't need is gone. The rest is fixed, machined geometry.

03

Offset with data and assay design

Peak tracking and reference channels, tuned for the larger shifts that larger targets give in complex samples.

Figure — lensless block close-up
Nothing to align, nothing to move, and every channel is a copy of the first.
Technical note: thin-film SPR and nanoparticle LSPR

Both use plasmons on gold. The difference is where the light travels and how far the sensing field reaches into the sample.

Thin-film SPR (Lensless SPR)Nanoparticle LSPR
Light pathReflects under the gold and never crosses the sample, so complex or opaque samples work.Passes through the sample, so samples need to be clear.
Sensing depth200–300 nm: room for larger targets and sandwich assays.20–30 nm: very surface-sensitive, with fewer assay formats.
SensitivityAbout 1800 nm/RIU near water, rising at longer wavelengthA few hundred nm/RIU
KineticsPlanar diffusion, consistent with most published SPR kinetics.Radial diffusion, with fewer reference publications.

Full comparison in TN-02: thin-film SPR and nanoparticle LSPR →

What replaced each part of a conventional bench
Conventional SPRLensless SPR
Collimating and focusing lensesAperture tunnels machined into the light path shape the LED light
Rotating stage and angle scanningWavelength interrogation at a fixed angle: a broadband LED and a spectrometer read the resonance by colour
Hemispherical prism, source and detector on angled armsDove prism: light leaves on the same axis it enters, so the whole path is one straight line
PolarizerPolarizer, kept
A full optical train for each channelOne LED and one sensing area per channel, with fibres feeding one shared spectrometer

WHAT IT MEANS FOR YOU

The instrument is no longer the hard part.

When the light path is a machined part, an SPR instrument can be small, simple, and identical from one channel to the next.

small-bsl2-hood-cartoon

SMALL

The lensless optical module fits within the footprint of an earbud case. Add the detector and the whole measurement is about the size of a pipette-tip box.

portable-field-cartoon

PORTABLE

A full instrument can travel in a carry-on and run on arrival.

YOUR BIOLOGY

The hard part moves to what you capture on the gold and how you design the assay.

Same light path in any sample
The light reflects under the gold and never crosses the sample, so detection in complex or opaque samples is possible.

INSIDE EVERY INSTRUMENT

One lensless core, three configurations.

The same four-channel optical block sits inside the P4SPR 2.0 and the P4PRO.

Image

Core

P4SPR 2.0

ModeStatic SPR
KineticsEndpoint binding and concentration
InjectionManual, 1 mL syringe
Best forBinding checks and method development in complex samples
Image

+ Kinetics

P4PRO with AffiPump

ModeStatic and flow
Kineticskon, koff and KD
InjectionPump-controlled injections
Best forFull kinetic characterisation
Screening platform: Nexas autosampler + AffiPump + P4PRO + P4SPR 2.0

+ Screening · New

Screening platform

ModeAutosampler + P4PRO with AffiPump + P4SPR 2.0
Kineticskon, koff and KD
InjectionAutosampler, 96-well plates
Best forPlate-based screening, with P4SPR 2.0 for quick static checks. Available to order

PROOF

80+ peer-reviewed publications using Affinité SPR

Protein A binding human IgG, from the raw data

P4PRO, protein A surface, human IgG at 0.41, 11.1, 33 and 100 nM. Coloured lines are measured data; thin lines are a global 1:1 fit.

“High quality data, right out of the box. The best small SPR platform we’ve used.”University of Lille

See all publications →

Beyond SPR

SPR alongside other methods

SPR rarely works alone. Our team and our users combine it with other analytical methods, on the same sensor or in the same workflow.

Electrochemistry

SPR and electrochemistry on one gold surface

Our eSPR work reads both signals from the same sensor; the two methods gave comparable performance for DNA hybridization.

The eSPR note →

Fluorescence

SPR and fluorescence on one chip

A single chip combining SPR with a fluorescent ELISA, shown for prostate-specific antigen.

The 2015 paper ↗

Microfluidics

Sample preparation upstream

A microfluidic plasma-separation device feeds the P4SPR to measure biomarkers straight from whole blood.

The whole-blood note →

Automation

Autosamplers and liquid handling

On the Screening platform an autosampler injects samples from well plates, run after run.

The Screening platform →

Reference methods

Checked against HPLC and ELISA

Our application notes compare SPR results with established methods, such as the HPLC reference method for explosives in water.

The RDX note →

Plasmonics

LSPR and SERS

Nanoparticle sensors read by LSPR and SERS, from the research publications of our team and users.

LSPR and SERS paper ↗

Combining SPR with your method? Tell us about it →